DRY HEAT STERILIZER
SALIENT FEATURES:

MICRO PROCESSOR FOR PROCESS OPERATIONS WITH 10 PROGRAMME
HEPA FILTERED AIR MODULE IN INLET
S.S. CONSTRUCTION
8 CHANNEL TEMPERATURE SCANNING WITH PROCESSOR
MIMIC DISPLAY ON CONTROL PANEL
DOOR INTER LOCKING
HELPS FOR FAULT FINDING
COOLING ATTACHMENT FOR RAPID COOLING
HEATERS ACCESSED FROM NON STERILE SIDE
TOTAL GMP MODEL 


HOT AIR STERLIZER
Description:

"RAVI" Hot Air sterilizer are made for Dry Sterilization of Vials, Ampoules, Containers and Bottles as well as for sterilizing powders, liquids for siliconizing. It is designed for a maximum temperature of 300oC and will be controlled by electronic digital temperature controller.

Sizes:

Five standard size and also custom built sterililzer to meet individual requirement.

Design and Construction:

Complete GMP models made out of S.S.304/316 Sheets 3mm thick external and 2mm thick internally.
There will be two doors, one on sterile side and other on non sterile side. Door lips will have silicon gasket to prevent air leakages.
There will be 4 point centrally locking device to ensure positive locking without any leakages.
Sterilizer will be insulated with 125 mm thick fibreglass insulation. Air inlet will be through Hepafilter and Exhaust will have a S.S.mesh filter. Both inlet and outlet will be automatically operated through control panel.

Heating:

Heating will be by "U" tube air heater made out of S.S. 304 and will be divided into 3 heater banks which will be operated automatically. The heating load will be according to the size of sterilizer. The entire heater assembly can be brought out from outside for maintainance, hence reducing the break down time. Also the heater terminals are brought outside the internal heating chamber to eliminate the problem of black particles.

Air Circulation:

Air inside the sterilizer will be circulated by a heavy duty centrifugal blower mounted on a suitable motor. The blower will suck the air from one side and force it on other side such that air current will pass over the entire charge loaded in the boxes.

Trolley:

Sterilizer One / Two trolleys according to the size of the internal chamber. Carriages will also be provided for main trolleys.



MODEL
CHAMBER SIZE
W.
D.
H.
ELECTRICAL
LOAD (KW)
CAPACITY FOR 5ML AMPOULES CAPACITY FOR 5.75ML VIALS
RS-01
865 X 810 X 1140
18
17500
15600
RS-02
1200 X 810 X 1140
21
27000
24200
RS-03
1200 X 1220 X 1140
27
41000
36800
RS-04
1200 X 1220 X 1350
30
49000
44000
RS-05
1200 X 1220 X 1775
33
57000
51000